Organ chips with integrated multifunctional sensors enable continuous metabolic monitoring at controlled oxygen levels

Organ Model: Small Intestine & Liver

Application: Organ-on-a-Chip Technology

Abstract: Despite remarkable advances in Organ-on-a-chip (Organ Chip) microfluidic culture technology, recreating tissue-relevant physiological conditions, such as the region-specific oxygen concentrations, remains a formidable technical challenge, and analysis of tissue functions is commonly carried out using one analytical technique at a time. Here, we describe two-channel Organ Chip microfluidic devices fabricated from polydimethylsiloxane and gas impermeable polycarbonate materials that are integrated with multiple sensors, mounted on a printed circuit board and operated using a commercially available Organ Chip culture instrument. The novelty of this system is that it enables the recreation of physiologically relevant tissue-tissue interfaces and oxygen tension as well as non-invasive continuous measurement of transepithelial electrical resistance, oxygen concentration and pH, combined with simultaneous analysis of cellular metabolic activity (ATP/ADP ratio), cell morphology, and tissue phenotype. We demonstrate the reliable and reproducible functionality of this system in living human Gut and Liver Chip cultures. Changes in tissue barrier function and oxygen tension along with their functional and metabolic responses to chemical stimuli (e.g., calcium chelation, oligomycin) were continuously and noninvasively monitored on-chip for up to 23 days. A physiologically relevant microaerobic microenvironment that supports co-culture of human intestinal cells with living Lactococcus lactis bacteria also was demonstrated in the Gut Chip. The integration of multi-functional sensors into Organ Chips provides a robust and scalable platform for the simultaneous, continuous, and non-invasive monitoring of multiple physiological functions that can significantly enhance the comprehensive and reliable evaluation of engineered tissues in Organ Chip models in basic research, preclinical modeling, and drug development.

Developing an RNA Signature for Radiation Injury Using a Human Liver-on-a-Chip Model

Organ Model: Liver

Application: Toxicology

How Organ-Chips Were Used: Here, users demonstrated the potential utility of a human Liver-Chip to model organ-specific radiation injury, providing a platform for the development of radiation medical countermeasure and for biomarker validation. Users also identified biomarkers of RILI and defined cell-specific targets for potential radiation mitigation therapies.

Products Used In This Publication

Evaluating the Hepatotoxicity of Cannabidiol, Cannabinol, Cannabichromene and Cannabigerol Using a Human Quad-Culture Liver-Chip

Abstract

As the popularity of hemp-derived products grows, understanding the prospective hepatotoxicity of cannabinoids becomes crucial for personal safety. Despite conflicting evidence from limited human clinical studies, a safety gap persists, and no standard threshold has been established for these various cannabinoid-containing products. Furthermore, the hepatotoxicity potential of other cannabinoids like Cannabinol (CBN), Cannabichromene (CBC), and Cannabigerol (CBG) remains largely unexplored.

The current study was designed to address some of these gaps by utilizing microphysiological systems (MPS), such as the Emulate Quad-Culture Liver-Chip, which adhere to IQ MPS consortia guidelines, as an alternative to animal testing. Here, pressure-driven flow for compound delivery was used with primary human cells in an in vivo-like arrangement, separated by a semi-porous membrane to allow for crosstalk between the hepatocytes and nonparenchymal cells (NPCs). Hepatotoxicity was compared among CBD, CBN, CBC, and CBG, in parallel with the known hepatotoxic compound acetaminophen (APAP), in a three-point concentration response evaluation (0.24, 3, or 4.7 µM). The assessment encompassed morphological effects, hepatocyte function, and potential mechanisms of action over a 7-day continuous dosing period. These evaluations included live imaging for mitochondrial dysfunction, total reactive oxygen species (ROS), and inflammatory cytokines derived from effluent-based sampling in the Emulate platform. 

Morphological analysis revealed 3 or 4.7 µM CBD impacting hepatocytes by Day 7, while CBG exhibited no visible changes compared to the control. Endpoints evaluating hepatocyte function and viability indicated that LDH release increased only with 4.7 µM CBD, CBN, and CBC. CBD, CBN, and CBG did not significantly affect albumin, ALT, or AST, while 4.7 µM CBC significantly decreased albumin production. Inflammatory cytokines increased at high concentrations of CBD, CBC, and CBG. ROS and mitochondrial function displayed different responses among the cannabinoids affecting the NPCs more versus the hepatocytes. Up until now, the majority of what is known regarding these compounds is mostly murine-based. Hence, this study was an effort to leverage the use of advanced, human-relevant MPS to carefully assess and compare the hepatotoxicity of CBD and other cannabinoids, shedding light on their safety in foods and health products.

Organ-on-a-chip for studying immune cell adhesion to liver sinusoidal endothelial cells: the potential for testing immunotherapies and cell therapy trafficking

Organ Model: Liver

Application: Immunology & Inflammation

Abstract: Immunotherapy has changed the landscape of treatment options for patients with hepatocellular cancer. Checkpoint inhibitors are now standard of care for patients with advanced tumours, yet the majority remain resistant to this therapy and urgent approaches are needed to boost the efficacy of these agents. Targeting the liver endothelial cells, as the orchestrators of immune cell recruitment, within the tumour microenvironment of this highly vascular cancer could potentially boost immune cell infiltration. We demonstrate the successful culture of primary human liver endothelial cells in organ-on-a-chip technology followed by perfusion of peripheral blood mononuclear cells. We confirm, with confocal and multiphoton imaging, the capture and adhesion of immune cells in response to pro-inflammatory cytokines in this model. This multicellular platform sets the foundation for testing the efficacy of new therapies in promoting leukocyte infiltration across liver endothelium as well as a model for testing cell therapy, such as chimeric antigen receptor (CAR)-T cell, capture and migration across human liver endothelium.

Beyond the hype and toward application: liver complex in vitro models in preclinical drug safety

Overview

Drug induced Liver-Injury (DILI) is a leading cause of drug attrition, and complex in vitro models (CIVMs)—including three dimensional (3D) spheroids, Organ-Chips, 3D bio printed tissues, and flow-based systems—could improve preclinical prediction. Although CIVMs have demonstrated good sensitivity and specificity, in DILI detection their adoption remains limited.

This article describes DILI, the challenges with its prediction and the current strategies, and the models that are being used to study it. It reviews data from industry-FDA collaborations and strategic partnerships and finishes with an outlook of CIVMs in preclinical toxicity testing.

On the potential of the Human Liver-Chip as a model of cholestatic toxicity

Abstract

Bile acids are an essential component of bile, which aids digestion in the form of emulsification and absorption of lipids. Primary bile acids (cholic and chenodeoxycholic acid) are synthesized in the liver, can be conjugated with glycine or taurine, concentrated in the gall bladder, and circulated to the intestine during digestion. Primary bile acids are converted to secondary bile acids (deoxycholic and lithocholic acid) by intestinal bacteria and are recirculated back to the liver via enterohepatic circulation. In a healthy liver, bile acids are secreted from hepatocytes into bile canaliculi through the bile salt export pump (BSEP) which is involved in maintaining bile acid homeostasis. When bile flow is disrupted, increasing levels of intrahepatic bile acids cause cholestatic injury. Cholestasis can be induced by drugs like troglitazone (TROG), a diabetes therapy that was discontinued after causing liver toxicity in clinical trials partly via inhibition of BSEP. To establish a physiologically relevant model of drug-induced cholestasis, Emulate’s human Quad-Culture Liver-Chip was incubated with bile acids in the presence or absence of TROG and monitored for signs of toxicity and BSEP inhibition. A mixture of glycine-conjugated primary and secondary bile acids, including glycocholic acid (GCA), glycodeoxycholic acid (GDCA) and glycochenodeoxycholic acid (GCDCA), were chosen as they are three of the most abundant bile acids in human serum (comprising ~68% of the
total population) and were administered at concentrations ranging from 1-5X human Cmax.

Evaluating the immunotoxicity of CD137-induced agonism on the Emulate Human Liver-Chip

Abstract

The field of cancer immunotherapy is rapidly growing but is challenged by our inability to predict treatment efficacy, patient response and adverse effects. Agonistic antibodies toward T cell co-stimulatory molecules like Urelumab (targeting CD137) are one class of immunotherapy that has shown unparalleled efficacy in murine models of cancer. However, in clinical trials (NCT00309023), Urelumab doses ≥ 1 mg/kg resulted in significant hepatotoxicity (mainly transaminitis), suggesting murine and NHP preclinical assessment failed to predict this clinical safety outcome. While the mechanism of clinical liver toxicity has not been fully elucidated, studies with humanized mice (with human hematopoietic cells) indicate immune-mediated DILI (drug-induced liver injury). Therefore, to model hepatotoxicity associated with Urelumab, we created a novel, immuno-competent human Quad-Culture Liver-Chip using human peripheral blood mononuclear cells (PBMCs) that contain lymphocytes, NK cells and CD137+ monocytes to drive immunotoxicity.

Identification of pharmacological inducers of a reversible hypometabolic state for whole organ preservation

Organ Model: Liver, Intestine (Caco2)

Application: Organ transplantation

How Organ-Chips Were Used: Drugs that induce reversible slowing of metabolic and physiological processes would have great value for organ preservation, especially for organs with high susceptibility to hypoxia-reperfusion injury, such as the heart. Here, Gut- and Liver-Chips were used to evaluate the metabolic suppression capability of the test compound. The Chips showed a decrease in the tissue’s total ATP production in presence of SNC80, which is accompanied by a global slowing of metabolism.

Products Used In This Publication

Human Liver-on-a-Chip to Predict and De-Risk Next Gen Therapeutics

Webinar Abstract

Featured session at Boston MPS Day, which took place on 11/1/2023.

In this presentation, Dr. Samantha Atkins from Moderna discusses the use of the Emulate human Liver-Chip to predict and understand toxicity mechanisms associated with lipid nanoparticle (LNP) and mRNA therapeutics. Traditional animal models, such as rodent studies, sometimes fail to predict adverse outcomes seen later in non-human primate (NHP) studies or clinical settings, particularly when novel LNP chemistries are involved. By leveraging the Emulate human Liver-Chip, Dr. Atkins aims to identify early signatures of fibrosis and other forms of liver damage, thereby guiding safer and more effective therapeutic design before proceeding to NHP studies.

Using the Liver-Chips, Dr. Atkins’ team demonstrated the ability to pinpoint gene signatures and collagen remodeling patterns corresponding to pro-fibrotic LNPs. This helps flag problematic compounds early, reducing reliance on costly and time-consuming animal studies. Moreover, the chips provided mechanistic insights into both LNP-driven and mRNA-mediated toxicity, revealing pathways such as necroptosis in certain constructs. Such mechanistic understanding helps tailor safer LNP formulations and mRNA constructs.

Key learnings from this presentation include:

  • Human liver-on-a-chip systems can successfully model liver fibrosis and flag toxicity that might be missed by animal models.
  • Early gene signatures identified on the chip correlate with adverse outcomes in NHP models, enabling preclinical down-selection of safer LNP candidates.
  • The platform aids in distinguishing between LNP-induced versus mRNA-mediated toxicity, offering valuable mechanistic insights.
  • Leveraging these in vitro models can save time and reduce costs associated with late-stage animal testing.
  • Mechanistic understanding of cell death pathways (e.g., necroptosis) informs rational modifications to improve therapeutic safety profiles.

The Utilization of Organ-on-a-chip Technology for Predictive Toxicology of Chemical and Biological Threats

Featured session at Bethesda MPS Day, which took place on November 9, 2023.

Dr. Dylan Fudge from the U.S. Army DEVCOM Chemical Biological Center discusses the use of Organ-Chip models, specifically Emulate’s MPS platforms, to advance the Army’s predictive toxicology efforts related to chemical and biological threats. Traditional safety and efficacy assessments often rely heavily on animal models and simplistic in vitro assays, which may not accurately reflect human physiology, particularly for acute, high-risk agents. By integrating human-relevant cells into microfluidic devices, Dr. Fudge’s team aims to improve mechanistic understanding, dose-response assessments, and long-term impact evaluations of nerve agents, PFAS compounds, and pathogens like SARS-CoV-2.

He showcases three major projects:

  1. VX Nerve Agent on Liver-Chip:
    Exposing a human Liver-Chip (with hepatocytes, endothelial cells, stellates, and Kupffer cells) to sub-lethal VX concentrations allowed for multi-omics analyses (proteomics, metabolomics, and transcriptomics). The system revealed shifts in metabolic pathways, bioenergetics, and nitrogen metabolism consistent with in vivo and clinical literature. Importantly, VX’s known mechanism—disruption of acetylcholine breakdown—was mirrored in altered choline metabolism, reinforcing the Liver-Chip’s translational relevance.
  2. PFAS Exposure in Kidney and Liver-Chips:
    Investigating polyfluoroalkyl substances (PFAS), the team saw patterns of compound retention and toxicity aligned with known clinical effects. Liver and Kidney-Chips demonstrated differential absorption and metabolic responses to PFAS, supported by robust omics data. Oxygen stress markers and biomarkers like uric acid levels recapitulated known toxicity profiles, indicating the chips’ capacity to model chronic, low-level exposures and related subtler health effects.
  3. SARS-CoV-2 Infection Using Lung-Chips:
    Lung-Chips incorporating airway and alveolar regions enabled controlled infection with SARS-CoV-2 variants. Despite minimal acute cytotoxicity, omics analyses detected hallmark inflammatory pathways and mechanistic insights matching emerging clinical findings—such as immune activation and potential neuro-related disease pathways—emphasizing the chip’s ability to reveal complex host-pathogen interactions.

Collectively, these studies highlight the versatility and reliability of Emulate’s Organ-Chip platforms under rigorous defense-oriented research conditions. Their capacity to maintain viable tissues, capture human-like biology, and provide high-content data (via omics) positions these systems as valuable tools to reduce animal use, support therapeutic development, and enhance understanding of chemical and biological threat agents at a mechanistic level.